Yongnuo YN-622C User's Guide Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 62
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
The Other YN-622C User Guide v.4.07
23/07/2014
Part II – 622C Transceivers Page 28 of 62
Flash Exposure Lock (FEL)
The camera must be in a creative mode.
Live View mode must be disabled.
Flash mode must be E-TTL.
First focus on subject.
Then press the camera’s [*] or [FEL] or [M-Fn] button, or as custom re-configured.
Flash metering temporarily changes to Spot metering. The ambient and flash exposures
are locked into the camera for 16 seconds, or while [half-shutter] remains pressed.
“FEL” appears momentarily, and the <Flash> icon and “*” are lit in the viewfinder. The
values are discarded when the shot is taken, or a hi-speed burst ends.
If the subject is too far away and underexposure may result, the <Flash> icon will blink in
the viewfinder. Move closer to the subject and try the FE lock again.
Flash Exposure Bracketing (FEB)
Set FEB in 1/3 f/stop increments up to -2 to +2 f/stops (-3 to +3 f/stops on 2012 and later
cameras).
The zero point for FEB is adjusted by the global FEC setting.
The sequence of FEB is fixed at 0 minus plus, even when the on-flash setting is
different.
The FEB function will be automatically cancelled after the three shots are taken.
An E-TTL flash which does not support FEB can also be used.
MANUAL MODE
User-determined Output Levels; No Metering
Remote Manual Levels
Type A camera menus can remotely control Mk II Speedlites and YN flashes.
All (global), groups A and B, or A, B and C.
Output levels 1/1 to 1/128, by Group
E-TTL Flashes do not emit a pre-flash
All Flashes (Global setting)
Set Flash Mode to Manual.
Set Flash Output as required, 1/1 to 1/128 output level, in 1/3 f/stop increments.
Either set Wireless function to Disable, or Enable Wireless with Firing Group A+B+C.
Two and three Receiver groups
Set Flash Mode to Manual.
Ignore Flash Output: it will repeat group A setting.
Set Wireless function to Enable.
Set Firing Group to A:B (C will not fire) or A:B C.
Set each Group Output as required, 1/1 to 1/128 output level, in 1/3-f/stop increments.
On-TX flash will fire at group A level, if Master Flash is enabled.
On-Flash Manual Levels
Type A, B or C cameras can trigger flashes where the output level has been set on-flash.
Flash connected by PC-sync cable.
Output levels set on individual flash.
E-TTL Flashes will not emit a pre-flash
Page view 27